≤75 ms Communication Refresh
Specified RS485 communication refresh time of ≤75 ms for applications requiring timely meter-side data updates.
DEM1E302 is a compact, single-phase, direct-connected DIN-rail energy meter for 1P2W systems, rated up to 45 A. It supports RS485 communication via Modbus RTU and DL/T 645-2007, with a specified RS485 communication refresh time of ≤75 ms. Battery-backed RTC, four TOU tariffs across eight time periods, and external tariff switching support time-based energy monitoring. DEM1E302 is suitable for AC-side monitoring in solar PV and BESS systems, AC EV charging, building submetering and industrial energy management.
MID

Specified RS485 communication refresh time of ≤75 ms for applications requiring timely meter-side data updates.
Class 0.5 active-energy measurement in accordance with IEC 62053-21 and Class 1 reactive-energy measurement in accordance with IEC 62053-23.
RS485 communication compatible with Modbus RTU and DL/T 645-2007 protocols, with configurable baud rates from 9.6 to 115.2 kbps and addresses from 1 to 247.
Supports forward, reverse, forward, reverse, absolute-value, algebraic-sum and forward/reverse offset calculation modes
Measures voltage, current, frequency, active and reactive power, power factor and energy, and calculates current and voltage harmonic content.
Provides EEP self-diagnosis and configurable alarms for monitored variables, with adjustable activation thresholds and delays.
Solutions for AC/DC charging, billing and charging platform integration.
Explore ApplicationDC/PV monitoring for inverters, storage systems and distributed energy monitoring.
Explore ApplicationBranch metering for buildings, factories, tenants and energy allocation.
Explore ApplicationRack, cabinet and distribution power monitoring for data center operations.
Explore Application| Wiring system | Direct connection, 1P2W |
| Rated voltage | 120-230V |
| Voltage tolerance | 0.8 to 1.15 Un |
| Frequency | 50/60Hz |
| Current connection | Direct connected |
| Basic current (Ib) | 5A |
| Minimum current (Imin) | 0.15A (MID) / 0.25A (IEC) |
| Maximum current (Imax) | 45A |
| Pulse constant | 1000 imp/kWh |
| Power consumption | <=2W / 10VA |
| Rated impulse withstand voltage | 6 kV |
| Voltage accuracy | ±0.5% |
| Current accuracy | ±0.5% |
| Frequency accuracy | ±0.5% |
| Active power accuracy | ±0.5% |
| Reactive power accuracy | ±1% |
| Active energy accuracy | Class 0.5 |
| Reactive energy accuracy | Class 1 |
| Communication interface | RS485 |
| Communication direction | Bidirectional |
| Protocols | Modbus RTU; DL/T 645-2007 |
| Modbus address | 1-247 |
| Baud rate | 9.6 / 19.2 / 38.4 / 57.6 / 115.2 kbps |
| Parity | None / Odd / Even |
| Refresh time | ≤75 ms |
| Display | Backlit LCD with automatic display cycling |
| Default display cycle | 5 seconds |
| LCD refresh time | 500 ms |
| LED | Red pulse LED |
| Buttons | Page turning and setting |
| Ingress protection | IP20 |
| Overvoltage category | OVC III |
| Protection class | Class II |
| Installation | 1P DIN rail |
| Operating temperature | -40°C to +70°C |
| Storage / transport temperature | -40°C to +70°C |
| Reference temperature | 25 ± 2°C |
| Relative humidity | ≤95%, non-condensing |
| Altitude | ≤2,000 m |
| Housing dimensions | 18 mm × 94 mm × 62.4 mm |
| Applicable standards | IEC 62052-11:2020 / IEC 62053-21:2020 / IEC 62053-24:2020 / EN 50470-3:2022 |
DEM1E302 supports RS485 communication with Modbus RTU and DL/T 645-2007 compatibility. Confirm the required register list, baud rate and system settings before deployment.
The current product specification lists a communication refresh time of ≤75 ms for the RS485 communication function. Actual end-to-end system performance also depends on controller polling, network configuration and system architecture.
Yes. DEM1E302 supports RTC and TOU tariff functions, with four tariffs and eight time periods as the default configuration.
Both models support 45A direct connection, RS485 communication, Modbus RTU, DL/T 645-2007 and ≤75 ms communication refresh. DEM1E302 adds battery-backed RTC and TOU tariff functions, while DEM1E202 is the no-battery version with tariff switching only.
No. DEM1E302 is an RS485 communication version. The SO pulse-output version in this series is DEM1E001.
Yes. The meter supports multiple energy-calculation modes, including forward and reverse energy measurement, absolute-value calculation and algebraic energy calculation.
It can be evaluated for AC-side solar PV, BESS, AC EV charging, building submetering and industrial energy-monitoring applications. Confirm wiring, current, communication and market requirements before selection.
Submit your project requirements and target market. Our team will confirm the applicable document version and provide the appropriate technical materials.
Official DEM1E series datasheet covering product overview, specifications, wiring and dimensions
Download DatasheetTell us your requirements and our team will provide a professional solution and quotation within 24 hours.