Adopt the standard sampling method of 75mV.and adopts RS485 communication for data transmission interaction.YTL DC meter DEM2D series Din-Rail 1P two wires Dual Channel CE Approved OEM Electric Meter
Adopt the standard sampling method of 75mV.and adopts RS485 communication for data transmission interaction.YTL DC meter DEM2D series Din-Rail 1P two wires Dual Channel CE Approved OEM Electric Meter
Type |
DEM2D002 |
DEM2D102 |
DEM2D003 |
DEM2D103 |
Voltage input: |
DC 5V~1000V |
DC 5V~1000V |
DC 5V~1000V |
DC 5V~1000V |
Auxiliary power supply |
85~300V AC or 85-300V DC |
85~300V AC or 85-300V DC |
DC 9-60V |
DC 9-60V |
Current: |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Accuracy current: |
0.5% |
0.5% |
0.5% |
0.5% |
Voltage Accuracy |
0.5% |
0.5% |
0.5% |
0.5% |
Active Power Accuracy |
1.0% |
1.0% |
1.0% |
1.0% |
Active Accuracy |
Class 1.0 |
Class 1.0 |
Class 1.0 |
Class 1.0 |
Constant: |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
LCD: |
LCD 6+2 |
LCD 6+2 |
LCD 6+2 |
LCD 6+2 |
Consumption: |
≤8VA ≤0.4W |
≤8VA ≤0.4W |
≤8VA ≤0.4W |
≤8VA ≤0.4W |
Temperature: |
-25~70℃ |
-25~70℃ |
-25~70℃ |
-25~70℃ |
Humidity: |
≤95% |
≤95% |
≤95% |
≤95% |
AC withstand voltage |
4400V/min |
4400V/min |
4400V/min |
4400V/min |
Impulse withstand voltage |
6.4kV - 1.2/50µS waveform
|
6.4kV - 1.2/50µS waveform
|
6.4kV - 1.2/50µS waveform
|
6.4kV - 1.2/50µS waveform
|
Battery |
NO |
YES |
NO |
YES |
Muti-tariff |
NO |
YES |
NO |
YES |
Relay |
NO |
YES |
NO |
YES |
● RS485 communication: used for parameter setting, data reading; DTL645 protocol/Modbus Protocol
● DC metering: using shunt sampling, high measurement accuracy; can measure DC power, current, voltage,
● Alarm function: Over-current alarm: When the current exceeds the CT1 value set by the meter, an alarm event occurs, and the alarm light on the electrical surface panel lights up (yellow light),
At the same time, the value of the corresponding alarm status register will change, and the user can read this register through communication to determine whether an over-current alarm has occurred.
● Display: LCD with backlight ,Support Various parameters display,energy data and Instantaneous parameters
● Firmware upgrade: RS485 local upgrade
Height 90mm
Width 36mm
Depth 73mm
confirms that this user guide has been read;
falling, please do not install, power on, and contact us in time;
with lead. It can be installed directly.
base should be fixed on a solid refractory wall with no corrosive gas in the air;
preferably with copper wire or copper terminal.
Established in 2000, Zhejiang Yongtailong Electronic Co., Ltd. is located in the center of Shanghai, Hangzhou and Suzhou cities. YTL is a professional China YTL EV Charging Electricity Meter 5~1000VDC Din-Rail Installation Suppliers and YTL EV Charging Electricity Meter 5~1000VDC Din-Rail Installation Company. With more than 20 years of energy metering experience, we devote ourselves to providing competitive projects and creating value for customers. YTL was one of the first companies in the domestic market with which had an internal R&D department as well as international sales business. Since our foundation in 2000 we have grown to a manufacturer which complies and meet to many specifications from our national and international partners. At present our export volume makes us a leading company for technology and product export to more than 50 countries throughout the world. With provincial high-tech enterprise R&D center, YTL is the Top 100-enterprise with most investment value in Zhejiang. And“Yongtailong”is the famous brand of Zhejiang. For any new products of customers, we will communicate with customers very professionally, listen to their opinions and give useful suggestions to ensure that excellent quality products are made.
Established In
Employees
Export Country
Design Right Patent
Smart meters play a vital role in the construction of smart cities. Smart city is a new urban model that uses information technology to improve the efficiency ...
In an era where energy efficiency and sustainability are paramount concerns, the role of multi-function energy meters in optimizing energy consumption cannot be...
The implementation of differentiated electricity billing by smart meters relies mainly on their advanced capabilities in measurement, communication, and data p...
IntroductionElectricity is an essential part of our daily lives, and the accurate measurement of electricity consumption is crucial for both consumers and utili...
Smart meters play a crucial role in accurately measuring and monitoring energy consumption, enabling utilities and consumers alike to make informed decisions ab...
With the rapid development of technology, smart technology has gradually penetrated into various areas of our lives, and the modern agricultural sector is no ex...